X-ray Fluorescence Analyzer for Precious Gold

X-ray Fluorescence Analyzer for Precious Gold

 Merchandise Description
It can qualitative and quantitation investigation among various resources except element C, also, the equipment can performance nicely in Mg,Al,Si,S,P, and Mn which other device can’t function properly. It primarily used in the following fields, this kind of as steel,  fireproofing, non-ferrous industry, the quality department, the plating thickness screening, ROSH inductor analysis and so forth.
 Primary Characteristics

(1).Precise: Test final results can be shut to examination soaked chemical strategies.

(two).Fast velocity: Testing big amounts elements in the sample only want handful of minutes.

(3).Non-loss: It are unable to harm the actual physical and chemical qualities in sample.

(4).Visually: Investigation benefits are existing immediately in graph.

(5).CZPT: It can not pollute the surroundings.
Main technical parameter

Examination factors Na-U,Mostly are Al,Si,P,S,K,Ca,Ti,V,Fe,Ni,Mn,Pb,Zn,Cu,Sn,Sb,As and so on
examination range one ppm-99.ninety nine%
measuring time All the contents analysis only in 1-2 minutes
investigation precision Standard deviation ≤0.08%
analysis error Up to the typical requirments
radiation dosage <25  μ sv/h
environment temperature fifteen ºC-35 ºC

Principal allocation

(1). Detection method

 Detector

 Type: electric refrigeration SDD detector

 Be window thickness: 50um

 The best resolution: 130eV

 CZPT response range: 1keV-50keV

(2).X light-weight tube (for X ray spectrometer)

 Voltage: ~ 50kV

 Maximum current: 1.0mA

 Maximum electrical power: 50W

 Filament voltage: two.0V

 Filament present: 1.7A

 Ray out angle: twelve °

 Target: Mo

 Be window thickness: .5mm

(three).Substantial-voltage electrical power provide

 Input voltage: DC+24V ± 10%

 Input existing: four.0A ( greatest )

 Output voltage: -5KV & 1mA

 Maximum electricity: 50W

 Voltage regulation price: .01% ( from no load to complete load)

 Current adjustment rate: .01% ( from no load to entire load)

 Ripple element: .one% ( P-P worth)

 The security of eight hours: .05%

(4). Vacuum pump

 Vacuum: vacuum check 20Pa limit vacuum 2Pa

 (five). Optical integration style / system / vacuum cavity radiation protection

 X gentle tube, detector, the composite filtertreatment method, CCD, positioning technique, computerized collimator switching technique processor optical path are built-in in a shut framework, ensure the security of optical technique with a shut optical path program as a vacuum cavity, by way of the loop and the maze effectively by employing X ray greatest energy at the same time to make certain the ray zero overflow.

Packing & CZPT



 

X-ray Fluorescence Analyzer for Precious Gold